NOTE
1: Ripple & Noise is measured by using 20MHz bandwidth limited osciloscope and terminated each output with a 0.1uFceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line.
2: Line regulation is defined by changing ± 10% of input voltage from nominal line at rated load.
3:Max.Power (W)≥Vo xlo
Electrical Specification
INPUT
● Input Range: 100 to 240VAC
● Frequency: 50 to 60Hz
● Input Current:≤2.5A
● Inrush Current: 35A/100VAC 70A/230VAC
● Hold Up Time:≥8.3ms
● Turn On Time:≤3s
OUTPUT
●Over Voltage Protection: Auto Recovery
●Short Circuit Protection: Auto Recovery
●Over Current Protection: Auto Recovery
●Over Temperature Protection: Auto Recovery
ENVIRONMENTAL
●Operating Temperature: 0 to 40℃
●Storage Temperature: -20 to 85℃
●Operation Humidity: 10% to 90 %
●Storage Humidity: 5% to 95 %
SAFETY
●Certified for the whole series: EN 62368-1,CE,In process