NOTE:
1: Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uFceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line.
2: Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
3 :Max.Power(W)≧Vo xlo
Electrical Specification
INPUT
·Input Range: 100 to 240VAC
·Frequency: 50 to 60Hz
·Input Current: ≦3.5A
·Inrush Current: 60A/100VAC 120A/230VAC
·Hold Up Time: > 8.3ms
·Turn On Time: ≦3s
OUTPUT
·Over Voltage Protection: Latch off
·Short Circuit Protection: Auto Recovery/Latch off
·Over Current Protection: Auto Recovery/Latch off
·Over Temperature Protection: Latch off
ENVIRONMENTAL
·Operating Temperature: 0 to 40℃
·Storage Temperature:-20 to 85℃
·Operation Humidity: 10% to 90 %
·Storage Humidity: 5% to 95 %
SAFETY
·Certified for the whole series:GB 4943.1,CCC
Mechanical Specification
·Case Size: 170Lx84Wx30H(mm)
·AC Inlet: c14,C8,C6
·Weight: 900 +/-10g