NOTE:
1: Ripole & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each outputwith a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line.
2: Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
3: Max.Power(W)≥Vo x lo
Electrical Specification
INPUT
● Input Range: 100 to 240VAC
● Frequency: 50 to 60Hz
● Input Current: ≤1.0A
● Inrush Current: 10A/100VAC 20A/230VAC
● Hold Up Time:≥8.3ms
● Turn On Time:≤3s
OUTPUT
●Over Voltage Protection: Auto Recovery
●Short Circuit Protection: Auto Recovery
●Over Current Protection: Auto Recovery
ENVIRONMENTAL
●Operating Temperature: 0 to 40℃
●Storage Temperature: -20 to 85℃
●Operation Humidity: 10% to 90 %
●Storage Humidity: 5% to 95 %
SAFETY
●Certified for the whole series: UL/CUL 62368-1.GB 4943.1.CCC