NOTE:
1: Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each outputwith a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line.
2: Line regulation is defined by changing t 10% of input voltage from nominal line at rated load.
3:Max.Power (W)≥Vo x lo
Electrical Specification
INPUT
●Input Range: 100 to 240VAC
●Frequency: 50 to 60Hz
●Input Current: ≦1.0A
●Inrush Current: 10A/100VAC 20A/230VAC
●Hold Up Time:≥8.3ms
●Turn On Time:≦3s
OUTPUT
●Over Voltage Protection: Auto Recovery
●Short Circuit Protection: Auto Recovery
●Over Current Protection: Auto Recovery
ENVIRONMENTAL
●Operating Temperature: 0 to 40℃
●Storage Temperature: -20 to 85℃
●Operation Humidity: 10% to 90 %
●Storage Humidity: 5% to 95 %
SAFETY
●Certified for the whole series: GB 4943.1, CCC